GILLETTE PORTABLE GENERATORS
|
Gen-Pro Series |
Compact Gen-Pro portable generator sets from 3 KW to 15 KW with heavy duty HONDA overhead valve design engines, unless noted. |
Heavy Duty,
long lasting portable power for contractor and rental use. If you want
clean, dependable emergency electric power, with the most reliable
engines, then GEN-PRO with HONDA, is the right choice for you.
These generator sets are made for the tough jobs where you need the
reliability, and that good clean emergency power will be there, when
you need it. This is exactly what you get, when you choose
GEN-PRO, because of it's many heavy duty and exclusive features.
Change, both rapid
and constant, is normal in today's technology. New and improved
methods are being developed at a record pace. Not only has GEN-PRO
kept up with these new and improved methods, we have also leaped
forward with our own unique and exclusive designs, as shown by the (6)
items below. Our
generators produce clean, reliable electric power. Couple this
with the HONDA OHV engines with dramatically reduced exhaust pollutions
(to comply with C.A.R.B. and EPA), makes GEN-PRO truly, a
"Kleen-Power"™ generator to use in virtually any application.
For those who
want and need the very best, GILLETTE GENERATORS give you an all USA
made, heavy duty generator with (6) exclusive features. The remaining
features are also randomly found on other competing generator sets. |
|
- EXCLUSIVE, "KLEEN-POWER"
design allows only 7% harmonic distortion of the generated power
sine-wave. Harmful harmonic distortions over 10% may do damage to
your plugged-in electric load.
- EXCLUSIVE, "POWER-ASSIST"
design allows 35% more copper wire and electrical grade steel
laminations than leading competitor gen-sets. This gives you huge
(50% surge over rated kw), extra starting power for hard starting
electrical motors.
- EXCLUSIVE, HEAVY DUTY DIODES gives you a "life time warranty" from failure on the most frequently replaced part on other brand gen-sets.
- EXCLUSIVE, HEAVY-DUTY CAPACITOR gives you "Life-Time" warranty from failure on the second most commonly replaced part on other brand gen-sets.
- EXCLUSIVE, AUTOMATIC LOAD BALANCE eliminates load chatter and excessive vibration due to unbalanced electric loads.
- EXCLUSIVE, INSULATION DESIGN gives you superior insulation against un-wanted heat for a longer lasting winding.
- CIRCUIT BREAKERS are the highest quality automatic protection available for generator from overloads and "short circuited" electric loads.
- GROUND FAULT CIRCUIT INTERRUPTERS (GFCI) receptacles help protect operator from electric shock and provides OSHA/NEC compliance on the construction job-site.
- VOLTMETER allows easy review of generator voltage output.
- RUN TIME METER totals the hours of run time for service or rental use.
- OVER-HEAD VALVE
engine gives you 20% smaller size and lighter weight, than less
efficient side valve engines. OHV design also reduces fuel and
oil consumption by 40%, give you up to 10% more torque, and meets EPA
and C.A.R.B. clean exhaust requirements for 2002.
- CAST IRON CYLINDER SLEEVE allows easy starting, trouble free operation, and longer service life.
- AUTOMATIC OIL SENSOR protects your engine from low oil level and automatically stops engine before damage happens.
- SOLID STATE IGNITION allows trouble free operation with no points or condenser to replace.
- 2-ELEMENT AIR CLEANER adds major additional engine life.
- ROPE-RECOIL STARTING is easy and simple with its unique automatic compression release.
- ELECTRONIC STARTING makes the large 9kw through 14kw a simple matter with just a turn of the key switch.
- EXTENDED RUN 4 GALLON fuel tank with filter, valve and fuel gauge, allows up to 12 hours continuous run on 3kw to 7.5kw sets.
- EXTENDED RUN 8 GALLON fuel tank with filter, valve and fuel gauge, allows up to 9 hours continuous run on 9kw to 14kw sets.
- BUILT IN 2 WHEEL DOLLY for ease of transport on 9kw-14kw generators. Optional dolly available for 3kw to 7.5kw.
- 50 HERTZ POWER AND THREE PHASE is available as options.
- 2 YEAR LIMITED WARRANTY is available with your choice of any HONDA driven generator set.
All generators are available with your choice of HONDA, VANGUARD, OR KOHLER heavy duty OHV engines.
| GEN-PRO
by GILLETTE, is a reliable and dependable electric power to go
anywhere. These lightweight and compact generators are designed
for extreme heavy duty and abusive conditions. These high portability
generators will let you plug into, clean dependable electric power,
virtually anywhere, anytime.
|
| |
SINGLE PHASE, 120/240 VOLTS, 60 HERTZ WITH ALL HONDA ENGINES |
| Generator Models |
GPN- 30H |
GPN- 40H |
GPN- 50H |
GPN- 50EH |
GPN- 65H |
GPN- 65EH |
GPN- 75H |
GPN- 75EH |
GPN- 125EH |
| Maximum KW |
3.0 |
4.0 |
5.0 |
5.0 |
6.5 |
6.5 |
7.5 |
7.5 |
12.5 |
| Prime KW |
2.8 |
3.0 |
4.5 |
4.5 |
6.0 |
6.0 |
6.5 |
6.5 |
11.0 |
| Prime Amps @ 120V. |
21 |
26 |
38 |
38 |
50 |
50 |
54 |
54 |
92 |
| Prime Amps @ 240V. |
N/A |
13 |
19 |
19 |
25 |
25 |
27 |
27 |
46 |
| |
SINGLE PHASE, 120/240 VOLTS, 60 HERTZ GENERATOR SETS |
| |
HONDA ENGINES |
VANGUARD ENGINES |
Vangaurd V-Twin |
Kohler |
| Generator Models |
GPNR-50H |
GPNR-65H |
GPNR-75EH |
GPNR-90E |
GPNR-125E |
GPN- 90E |
GPN- 105E |
GPN- 125E |
GPN- 150EC |
| Maximum KW |
5.0 |
6.5 |
7.5 |
9.0 |
12.5 |
9.0 |
10.5 |
12.5 |
15.0 |
| Prime KW |
4.5 |
6.0 |
6.5 |
8.0 |
11.0 |
8.0 |
9.5 |
11.0 |
13.5 |
| Prime Amps @ 120V. |
38 |
50 |
54 |
66 |
92 |
66 |
80 |
92 |
112 |
| Prime Amps @ 240V. |
19 |
25 |
27 |
33 |
46 |
33 |
40 |
46 |
56 |
| PRICING |
|
|
SPECIFICATIONS FOR GEN-PRO PORTABLE GENERATORS, USING HONDA, HEAVY DUTY, OVERHEAD VALVE ENGINES EXCEPT AS NOTED. ALL SETS ARE GASOLINE FUELED WITH EXTENDED RUN FUEL TANKS |
|
GENERATOR MODELS |
SINGLE PHASE, 120/240 VOLTS, 60 HERTZ WITH ALL HONDA ENGINES |
| GPN-30H |
GPN-40H |
GPN-50H |
GPN-50EH |
GPN-65H |
GPN-65EH |
GPN-75H |
GPN-75EH |
GPN-125EH |
| GENERATOR REGULATION |
ALL MODELS : PLUS OR MINUS 5% FROM NAMEPLATE RATING |
| FREQUENCY REGULATION |
ALL MODELS : PLUS OR MINUS 5% FROM NAMEPLATE RATING |
| "KLEEN-POWER"TM |
ALL MODELS : WAVEFORM DISTORTION AVERAGES 6% - 7% |
| ENGINE BRAND |
ALL MODELS : HONDA, OVERHEAD VALVE, AIR COOLED ENGINES |
| ENGINE MODELS |
GX160 |
GX200 |
GX270 |
GX270 |
GX390 |
GX390 |
GX390 |
GX390 |
GX620 |
| ENGINE STARTER |
ROPE RECOIL |
ROPE RECOIL |
ROPE RECOIL |
ROPE & ELECTRIC |
ROPE RECOIL |
ROPE & ELECTRIC |
ROPE RECOIL |
ROPE & ELECTRIC |
ELECTRIC |
| ENG. HP/3600 RPM |
5.5 |
6.5 |
9.0 |
9.0 |
13.0 |
13.0 |
13.0 |
13.0 |
20.0 |
| ENG. CU. CENTIMETER |
160 |
196 |
270 |
270 |
389 |
389 |
389 |
389 |
620 |
| ENGINE CYLINDERS |
ALL MODELS : SINGLE CYLINDER WITH CAST-IN IRON CYLINDER WALL |
2 V-TWIN |
| LOW OIL PROTECTION |
ALL MODELS : STANDARD ENGINE SHUT-DOWN PROTECTION |
| db(A) AT 7 METERS |
73 |
74 |
76 |
76 |
77 |
77 |
78 |
78 |
86 |
| FUEL TANK (GAL.) |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
8 |
| 3/4 LOAD RUN TIME (HRS) |
10.0 |
9.0 |
6.7 |
6.7 |
4.7 |
4.7 |
4.2 |
4.2 |
6.0 |
| FUEL USE (GAL/HR) |
.40 |
.44 |
.60 |
.60 |
.84 |
.84 |
.95 |
.95 |
1.3 |
| CODE G, ELECTRIC MOTOR STARTING POWER |
1 HP |
1 HP |
1.5 HP |
1.5 HP |
2 HP |
2 HP |
2.5 HP |
2.5 HP |
5 HP |
| BUILT-IN DOLLY KIT |
PART #G-12 IS OPTIONAL 2-WHEEL DOLLY FOR ALL (8) MODELS |
YES |
| MAIN CIRCUIT BREAKER |
ALL MODELS : MAIN LINE AUTOMATIC CIRCUIT BREAKER PROTECTING WINDINGS AND INDIVIDUAL CIRCUIT BREAKERS PROTECTING EACH RECEPTACLE. |
| VOLT & HOUR METER |
ALL MODELS : STANDARD EQUIPMENT ON CONTROL PANEL |
| 120 VOLT RECEPTACLES |
ALL MODELS : (4) NEMA 5-15R, 120 VOLT, 20 AMP WITH GROUND FAULT CIRCUIT INTERRUPTERS (GFCI) |
NEMA L5-30R |
| 120/240 VOLT RECEPTS. |
N/A |
(1) NEMA L14-20R T-LOCK |
(1) NEMA L14-30R TWIST-LOCK |
N. 14-50R |
| LENGTH, INCHES |
26 |
26 |
26 |
28 |
28 |
28 |
28 |
28 |
35 |
| WIDTH, INCHES |
20 |
20 |
20 |
22 |
22 |
22 |
22 |
22 |
24 |
| HEIGHT, INCHES |
21 |
21 |
21 |
22 |
22 |
22 |
22 |
22 |
26 |
| NET WEIGHT (LBS.) |
131 |
139 |
170 |
187 |
193 |
208 |
200 |
215 |
305 |
| SHIP WEIGHT (LBS.) |
147 |
155 |
186 |
203 |
209 |
224 |
216 |
231 |
325 |
| CU.FT. AREA - SHIP BOX |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
16 |
|
GENERATOR MODELS |
SINGLE PHASE, 120/240 VOLTS, 60 HERTZ GENERATOR SETS |
|
VANGUARD V-TWIN |
KOHLER |
| GPN- 90E |
GPN- 105E |
GPN- 125E |
GPN- 150EC |
| GENERATOR REGULATION |
ALL MODELS : PLUS OR MINUS 5% FROM NAMEPLATE RATING |
| FREQUENCY REGULATION |
ALL MODELS : PLUS OR MINUS 5% FROM NAMEPLATE RATING |
| "KLEEN-POWER"TM |
ALL MODELS : WAVEFORM DISTORTION AVERAGES 6% - 7% |
| ENGINE BRAND |
VANGUARD, AIR COOLED, OHV |
KOHLER, AIR COOLED, OHV |
| ENGINE MODELS |
303447 |
350447 |
351447 |
CH25 |
| ENGINE STARTER |
ALL MODELS : HAVE AN ELECTRIC STARTER |
| ENG. HP/3600 RPM |
16 |
18 |
20 |
25 |
| ENG. CU. CENTIMETER |
480 |
570 |
570 |
725 |
| ENGINE CYLINDERS |
2 V-TWIN |
2 V-TWIN |
| ENGINE MUFFLER |
LO-TONE |
SUPER LO-TONE |
| LOW OIL PROTECTION |
ALL MODELS : STANDARD ENGINE SHUT-DOWN PROTECTION |
| db(A) AT 7 METERS |
79 |
80 |
81 |
88 |
| FUEL TANK (GAL.) |
8 |
8 |
8 |
8 |
| 3/4 LOAD RUN TIME (HRS.) |
9.0 |
8.5 |
6.0 |
5.0 |
| FUEL USE (GAL/HR) |
.87 |
.95 |
1.3 |
1.6 |
| FULL PRESSURE OIL LUBE WITH SPIN-ON FILTER |
YES |
YES |
YES |
YES |
| CODE G, ELECTRIC MOTOR STARTING POWER |
3 HP |
4 HP |
5 HP |
5 HP |
| BUILT-IN 2 WHEEL DOLLY |
YES |
YES |
YES |
YES |
| MAIN CIRCUIT BREAKER |
ALL MODELS : MAIN LINE AUTOMATIC CIRCUIT BREAKER PROTECTING WINDINGS AND INDIVIDUAL CIRCUIT BREAKERS PROTECTING EACH RECEPTACLE. |
| VOLTMETER & HOURMETER |
ALL MODELS : STANDARD EQUIPMENT ON CONTROL PANEL |
| 120 VOLT RECEPTACLES |
(4) NEMA 5-15R, 120 VOLT, 20 AMP WITH GROUND FAULT CIRCUIT INTERRUPTERS (GFCI) |
| (1) NEMA L5-30R TWIST-LOCK RECEPTACLE |
(1) NEMA L5-30R |
| 120/240 VOLT RECEPTACLE |
(1) NEMA 14-50R TWIST-LOCK RECEPTACLE |
(1) NEMA 14-60R |
| LENGTH, INCHES |
35 |
35 |
35 |
37 |
| WIDTH, INCHES |
24 |
24 |
24 |
26 |
| HEIGHT, INCHES |
26 |
26 |
26 |
29 |
| NET WEIGHT (LBS.) |
266 |
291 |
300 |
337 |
| SHIP WEIGHT (LBS.) |
286 |
311 |
320 |
357 |
| CUBIC FOOT AREA OF SHIPPING BOX |
16 |
16 |
16 |
22 |
|
GENERATOR MODELS |
SINGLE PHASE, 120/240 VOLTS, 60 HERTZ GENERATOR SETS |
| GPNR-50H |
GPNR-65H |
GPNR-75EH |
GPNR-90E |
GPNR-125E |
| GENERATOR REGULATION |
ALL MODELS : PLUS OR MINUS 5% FROM NAMEPLATE RATING |
| FREQUENCY REGULATION |
ALL MODELS : PLUS OR MINUS 5% FROM NAMEPLATE RATING |
| "KLEEN-POWER"TM |
ALL MODELS : WAVEFORM DISTORTION AVERAGES 6% - 7% |
| ENGINE BRAND |
HONDA, OVER HEAD VALVE |
VANGUARD, OHV |
| ENGINE MODELS |
GX270 |
GX390 |
GX390 |
303447 |
351447 |
| ENGINE STARTER |
ROPE RECOIL |
ROPE RECOIL |
ROPE & ELECT. |
ELECTRIC |
ELECTRIC |
| ENG. HP/3600 RPM |
9 |
13 |
13 |
16 |
21 |
| ENG. CU. CENTIMETER |
270 |
389 |
389 |
480 |
570 |
| ENGINE CYLINDERS |
1 |
1 |
1 |
2 V-TWIN |
2 V-TWIN |
| ENGINE MUFFLER |
ALL MODELS : SUPER LO-TONE |
| LOW OIL PROTECTION |
ALL MODELS : STANDARD ENGINE SHUT-DOWN PROTECTION |
| db(A) AT 7 METERS |
76 |
77 |
78 |
79 |
81 |
| FUEL TANK (GAL.) |
4 |
4 |
4 |
8 |
8 |
| 3/4 LOAD RUN TIME (HOURS) |
6.7 |
4.7 |
4.2 |
9.0 |
6.0 |
| FUEL USE (GAL/HR) |
.60 |
.84 |
.95 |
.87 |
1.3 |
| FULL PRESSURE OIL LUBE WITH SPIN-ON FILTER |
NO |
NO |
NO |
YES |
YES |
| CODE G, ELECTRIC MOTOR STARTING POWER |
1.5 HP |
2 HP |
2.5 HP |
3 HP |
5 HP |
| BUILT-IN 2 WHEEL DOLLY |
PART NO. G-12, 2 WHEEL DOLLY KIT IS OPTIONAL EQUIPMENT |
YES |
YES |
| MAIN CIRCUIT BREAKER |
ALL MODELS : MAIN LINE AUTOMATIC CIRCUIT BREAKER PROTECTING WINDINGS AND INDIVIDUAL CIRCUIT BREAKERS PROTECTING EACH RECEPTACLE. |
| VOLTMETER & HOURMETER |
ALL MODELS : STANDARD EQUIPMENT ON CONTROL PANEL |
| 120 VOLT RECEPTACLES |
(4) NEMA 5-15R, 120 VOLT, 20 AMP WITH GFCI GROUND FAULT PROTECTION |
| N/A |
(1) NEMA L5-30R |
| 120/240 VOLT RECEPTACLE |
(1) NEMA L14-20R |
(2) NEMA L14-30R |
(1) NEMA L14-30R |
(1) NEMA 14-50R |
(1) NEMA 14-50R |
| LENGTH, INCHES |
26 |
28 |
28 |
35 |
35 |
| WIDTH, INCHES |
20 |
22 |
22 |
24 |
24 |
| HEIGHT, INCHES |
21 |
22 |
22 |
26 |
26 |
| NET WEIGHT (LBS.) |
180 |
203 |
225 |
276 |
310 |
| SHIP WEIGHT (LBS.) |
196 |
219 |
241 |
296 |
330 |
| CU.FT. AREA - SHIP BOX |
10 |
10 |
10 |
16 |
16 |
| GENERATOR DESIGN :
Applications are for heavy duty, long running and abusive conditions.
We refer to these gen-sets, as "Contractor" and "Rental" reliable
generators. Only the best long endurance life engines are
used. The control panel is designed for rough conditions, using
magnetic circuit breakers, GFCI "Shock Proof" receptacles , special
grounded 4-wire, 120/240 volt receptacles, extended run fuel tanks,
full wrap-around protective carry frame and weather / sound engine
cover. As with all Gillette products, all generators produce clean
emergency electric power. "Kleen-Power", with only 6% average
harmonic wave-form distortion. Part No G-12 two-wheel dolly kit
is available up to 7.5 KW. Model GPN-125EH has it's own built-in
2-wheel dolly. A 2-year limited warranty is offered on these
GEN-PRO sets. |
|
PORTABLE GENERATOR SET ACCESSORIES |
|
ITEM NO. |
ITEM |
Description |
| - 3 |
3 Phase, 60 Hertz Special Winding |
Special
3 phase winding on any generator for 208, 220, 240, or 480 volts
(select only one voltage at time of order) 3 phase power with load
terminal strip located in control panel. Generator ratings are shown in
KVA, based on .8 power factor. (For BDN, GPN, GPND, and GPWD models
only, 7.5 kw to 15 kw gen-sets.) |
| - 5 |
50 Hertz Winding for 2-Pole, 3000 RPM sets |
Special
winding allows any model to produce voltage at 50 hertz. For use in
certain sections of the world that have this type of power. Derate 60
hertz wattage and amp ratings by 15%. Speed is reduced to 3000 rpm. |
| G10 |
3 Phase Receptacle (for mounting on panels for 6.5 thru 16kw) |
All
3 phase windings are equipped with a load terminal strip for permanent
wired installations. A 4-wire, 3 phase receptacle is mounted flush on
panel for portable (or easy power take-off) applications. A matching
male plug is furnished loose for complete set. |
| G12 |
Two-Wheel Dolly Kit |
Kit
is shipped disassembled and has axle, handles, and 2 full pneumatic
wheels, size 10" dia. x 4" wide. Fits all GPN, GPND, and PP portable
generators, 3.0 to 7.5 kw. All larger sizes, 9.0 kw thru 15 kw, have
built in 2 wheel full pneumatic 10” tires & lifting hook supplied
as standard equipment. |
| G13 |
Ground Fault Circuit Interrupter (GFCI) for 240 Volt Circuits |
OSHA
requires GFCI "Shock Protection" on all electrical, 120 VAC circuits at
job-site. We provide this protection on all Gen-Pro sets.
However, certain applications require this GFCI protection on the 240
VAC circuits. This is now available as an option, to protect all 120
and 240 Volt receptacles. |
| G14 |
Remote START-STOP Control Panel |
(G-15A) 3 button START-STOP Panel for all Kubota diesel engines with pre-heat starting. |
| G18 |
Loose Male Cap Plug to fit Mounted Generator Receptacles |
G15-1 |
NEMA Number 5-15P = 15 AMP, 120 Volt, 1 Phase, 3 Wire Male Cap |
| G15-2 |
NEMA Number 5-20P = 20 AMP, 120 Volt, 1 Phase, 3 Wire Male Cap |
| G15-3 |
NEMA Number L5-30P = 30 AMP, 120 Volt, 1 Phase, 3 Wire Male Cap |
| G15-4 |
NEMA Number L14-20P = 20 AMP, 120/240 Volt, 1 Phase, 4 Wire Male Cap |
| G15-5 |
NEMA Number L14-30P = 30 AMP, 120/240 Volt, 1 Phase, 4 Wire Male Cap |
| G15-6 |
NEMA Number 14-30P = 30 AMP, 120/240 Volt, 1 Phase, 4 Wire Male Cap |
| G15-7 |
NEMA Number 14-50P = 50 AMP, 120/240 Volt, 1 Phase, 4 Wire Male Cap |
| G15-8 |
NEMA Number 14-60P = 60 AMP, 120/240 Volt, 1 Phase, 4 Wire Male Cap | |